Fujikura FSM-50S Fiber Fusion Splicers

The FSM-50S Fusion Splicer is the new standard in fiber splicers featuring 9 second splice time and 35 second tube heating time. The 50S Arc splicer is a modern marvel of splicing with its sleek profile, light packaging and terrific performance. The 50S is optimal for field use. Key Features:Fujikura 50s Fusion Splicer

  • PAS Core to Core Fiber Alignment System: The Performance Alignment System platform in effect
  • Dual-Directional Operating System: Ergonomic reverse monitor allows for terrific ease of use.
  • Calibration-Free Arc System: No longer deal with time-consuming arc calibration, the FSM50S automatically calibrates on its own.
  • Optional Large Capacity slot-in batteries Offering two types of slot-in batteries: BTR-06S and BTR-06L
  • 9 Second Splice Time: New stepping motor and top notch computer processing allow for a 9 second splice with SM fiber.
  • 35 Second Tube-Heat Time: With FP-03 protection sleeve, achieve 35 second tube-heat time thanks to Advanced Heater Design.

Standard Package Includes: FSM-50S Arc Fusion Splicer ADC-11 AC Adapter Battery Charger, DC Inlet CC-12 Carrying Case MC-02 Monitor Cover ACC-XX AC Power Cord ELCT2-20A Spare Electrodes Instruction Manual for FSM-50S Optional Items: BTR-06S or BTR-06L Detachable Battery Pack DCC-10 Battery Charge Cord DCC-12 Cigarette Lighter Socket Type DC Power Cord DCC-13 Alligator Clamp Type DC Power Cord JP-04 J-Plate WT-06 Working Table WTS-06 Working Table Support MGS-05 Magnifying Glass CT-20 Series High Precision Fiber Cleaver PS-02 Primary Coat Stripper JS-01 Nylon Jacket Stripper SH-7 Tube Heater HR-1 Alcohol Dispenser FP-03 / 03 (L=40), FPS01 Series Protection Sleeves, Fiber Sleeves

SPECIFICATIONS
Fibre types : Singlemode (ITU-T G.652), multimode (ITU-T G.651), dispersion shifted (ITU-T G.653), non-zero dispersion shifted (ITU-T G.655)
Average Splice Loss : 0.02dB with G.652, 0.01dB with G.651 and 0.04dB with G.653 and G.655
Return Loss : 60dB or greater
Fibre Coating : 100μm to 1000μm
Fibre Cladding : 80μm to 150μm
Fibre Cleave Length : 8 to 16mm with coating diameter of 250μm or less. 16mm with coating diameter of 250μm to 1000μm
Splice Protector Heater : For all standard and micro splice protectors with protection sleeve centering device
Atmospheric Compensation : Automatic up to 3500 metres altitude with temperature and humidity compensation
Proof Test : 1.96N (200gf) standard or 4.41N (450gf) option, mechanical proof test
Fibre Viewing Method : Dual CCD cameras and 5.6” TFT colour LCD monitor
Magnification : 295x for single X and Y views. 147x for X/Y view
Splice Data Storage : 2000 splice data records
Interface : USB 1.1 for PC interface. RCA video jack
Power Supply : AC : 100 to 240V via AC adaptor ADC-11
DC Input: 10 to 15V via ADC-11
Detachable Battery Option : BTR-06S, 4.5Ah, (equivalent splice/shrinks : 60) BTR-06L, 9.0Ah, (equivalent splice/shrinks : 120)
Dimensions (WxDxH) : 150mm x 150mm x 150mm
Weight : 2.8kg including AC adaptor
Operating Temperature : -10°C to +50°C
Storage Temperature : -40°C to +80°C

  Opinion: The Fujikura 50s was a successful splicer for Fujikura but actual little difference between the FSM-40s, FSM-50s and FSM-60s. Each models is similar to the last, except of course that the 60s was ruggedized and includes an updated case.

Fujikura FSM-30S Fusion Splicer

Fujikura FSM-30S Singlemode / Multimode Fiber Fusion Splicer offers fully automatic operation, programmable tube heating cycle and a splice loss control function. Key Features:

  • Fully automatic operation once fibers are set in the fixture
  • Observation of both X and Y axis simultaneously
  • Atmosphere, humidity and temperature compensation functions provided
  • Mechanical proof test provided
  • Automatically stores the last 100 splice losses together with dates. Optional built-in memory card slot for storing additional splices.
  • Mode field diameter mismatch compensation splicing programs. Suitable for splicing two different fibers.
  • Splice loss control function
  • Arc power is optimized automatically by an integrated arc power test
  • Programmable tube heating cycle
  • Dust detection